SRS100
Wagner | SRS™ Sprue Removal System [2 pcs]
- In stock, ready to ship
- Backordered, shipping soon
Remove blue-state lithium disilicate sprues faster—then smooth the interface.
Wagner SRS™ combines connector removal and interface smoothing in one two-function rotary instrument, helping dental laboratories make the finishing step more controlled and repeatable.
Quick answer
The Wagner SRS™ Sprue Removal System is designed for blue-state milled lithium disilicate before final crystallization. Use the white diamond-infused section to remove the sprue connector, then use the blue section to smooth and polish the connector-to-restoration interface. Each package contains two instruments.
Remove the sprue connector
The white diamond-infused section is designed to remove the milled connector efficiently while giving the technician a defined first step.
Smooth and polish the interface
The blue diamond-infused section follows connector removal to smooth and polish the transition between the sprue and restoration.
Two functions in one instrument
The two-stage design keeps connector reduction and surface refinement in one instrument, reducing unnecessary tool changes during the sprue-removal step.
Two instruments per package
Each package contains two Wagner SRS™ instruments. Choose the quantity option above that best matches your routine case volume.
A clearer lithium disilicate finishing sequence
Separate connector removal from final interface refinement so each step has a defined purpose.
Built for the difficult blue-state sprue step.
Blue-state milled lithium disilicate before final crystallization is already hardened, which can make connector removal and smoothing slow or awkward with a general-purpose approach.
Wagner SRS™ creates a deliberate two-step process: reduce the connector with the white section, then smooth and polish the interface with the blue section.
- Purpose-built for blue-state lithium disilicate before final crystallization
- Defined connector-removal and interface-smoothing steps
- Fewer instrument changes during sprue removal
- More repeatable finishing sequence for technicians
- Two SRS™ instruments per package
Confirm that SRS fits your workflow.
Clear product fit reduces trial-and-error and helps prevent ordering the wrong rotary instrument.
Use for manufacturer-approved blue-state milled lithium disilicate before final crystallization workflows.
Connector removal followed by smoothing and polishing at the connector-restoration interface.
Two instruments per package. Select one or two packages using the quantity options above.
Choose the restorative material first—then match the finishing workflow.
Compare crystallization-based and no-crystallization CAD/CAM glass-ceramic options available from Gro3X.
XTCERA Glass Ceramic Milling Blocks
Explore lithium-disilicate-enhanced CAD/CAM blocks offered in HT, MT, and LT translucencies for veneers, inlays, onlays, partial crowns, and anterior or posterior crowns.
Shop XTCERA Glass CeramicAidite cameo KrystaFree CAD/CAM Blocks
Compare a polishing-based CAD/CAM glass-ceramic workflow that does not require crystallization. Its processing sequence differs from blue-state lithium disilicate.
Explore Aidite cameo KrystaFreeAlways follow the current restorative-material Instructions for Use and confirm rotary-instrument compatibility before processing.
Watch the Wagner SRS™ workflow.
See how the two sections are used sequentially to remove the connector and refine the restoration interface.
Wagner SRS™ frequently asked questions
Direct answers for dental laboratories evaluating a sprue-removal instrument for milled lithium disilicate.
What is the Wagner SRS™ Sprue Removal System?
It is a two-function rotary instrument designed to remove a sprue connector from blue-state milled lithium disilicate and then smooth and polish the connector-to-restoration interface.
What material is Wagner SRS designed for?
Wagner SRS™ is described for blue-state milled lithium disilicate before final crystallization. It should not be treated as a universal finishing instrument for every ceramic or restorative material.
How does the two-step SRS design work?
First, use the white diamond-infused section to reduce and remove the connector. Second, use the blue section to smooth and polish the interface where the sprue met the restoration.
How many instruments are included?
Each package contains two Wagner SRS™ instruments.
Does Wagner SRS replace the complete polishing sequence?
No. SRS focuses on sprue connector removal and interface smoothing. Complete the remaining adjustment, crystallization, finishing, and polishing steps required by the restorative material manufacturer.
Can SRS be used with every glass-ceramic block?
No universal compatibility is implied. Glass-ceramic materials can use different processing stages, including crystallization-based and no-crystallization workflows. Follow the current material Instructions for Use and confirm instrument compatibility.
Where can I buy compatible glass-ceramic CAD/CAM materials?
Gro3X offers XTCERA Glass Ceramic Milling Blocks and Aidite cameo KrystaFree CAD/CAM Blocks. Compare their processing requirements before selecting the finishing workflow.